Measurement Accuracy
Accuracy linear range
Flow Range (Re > 20,000):
Liquid Gases/Steam: ± 1 % of rate(stand)
Liquid ± 0.5 % of rate(option)
Reproducibility
£ 0.3 % of rate
Operating Pressure:
Flange design: DIN PN 10 to 40, option to PN 64
ANSI Class 150/300
Wafer design: DIN PN 10 to 40, option to PN 100
ANSI Class 150/300,option to600lbs
Additional designs upon request.
Connections:
Process Connections
Flanges , Wafer
Electrical Connections
Screw terminals, cable connector PG 13.5
Protection Class:
IP 65
IP68 for diving type(option)
Explosions Proof Design:
Ex ib IIC T6
Ex d IIC T6
Output:
Analog: 4-20 mA (for VT/VTD)
Pulse: high
Supply voltage
16 to 42 V dc for VT/VTD
12 or 24 V dc for VM
Materials:
Meter Housing ,Shedder Body,
Stn. stl. 0Cr18Ni9[304], option: 316Ti Hastelloy-C
Flanges Stn. stl. 0Cr18Ni9[304], option: 316Ti Hastelloy-C(wafer design without)
Sensor
Stn. stl. 0Cr18Ni9[304], option: 316Ti Hastelloy-C
Sensor Seals:
Graphite:-55 °Cto320 °C
Other materials upon request.
Housing, Electronic Assembly
Cast light metal, painted
Weight:
See dimension drawing Fig
Fluid Temperature:
-40 °Cto +320 °C(Standard)
-40 °Cto +350 °C(option)
-40 °Cto +280 °C(Ex-Design)
Ambient Conditions:
Relative humidity: max. 85 %, yearly average £ 65 %
Ambient-/Fluid Temperature:
-20℃----75℃